Freightliner — Freightliner Business Class M2 Workshop Manual

Chassis Electrical Control Systems 54.40 Tag/Pusher Axle Lift Troubleshooting Tag/Pusher Axle Lift For electrical troubleshooting of the tag/pusher axle lift, see Table 1 . Tag/Pusher Axle Lift Troubleshooting Symptom Possible Cause Check For Blinking indicator on the axle lift switch. No feedback. Damaged feedback circuit. Reverse caster axle not responding. Insufficient air pressure. If air pressure gauge indicates sufficient pressure, there may be a kink or restriction in the air line to the caster cylinder. Defective air management unit (AMU)/auxiliary air valve assembly (AAVA) solenoid. Remove the air line from the caster angle cylinder.

See if air is present when vehicle is placed in reverse. If no air, replace the suspect solenoid. Defective reverse caster air cylinder. If the air supply at the reverse caster cylinder proves good, replace the cylinder. Axle lift may engage then drop out, or not engage at all. Insufficient air pressure. If air pressure gauge indicates sufficient pressure, there may be a kink or restriction in the air lines. Defective AMU/AAVA solenoid. Remove the air line from one of the axle lift air bags. Test that air supply is controlled by axle lift switch. Repeat for all axle air bags. If air supply at air bag is not properly responding to the switch requests, replace the suspect solenoid.

Wiring fault to the pressure feedback switch circuit. Inspect grounds. Clean or repair as needed. The electrical connection to the AMU/AAVA solenoid is defective. Inspect connector and pins. Straighten bent pins and make sure that electrical connections are properly seated. Wiring fault in the ground to solenoid or pressure switch circuit. Inspect grounds. Clean or repair as needed. Table 1, Tag/Pusher Axle Lift Troubleshooting Business Class M2 Workshop Manual, Supplement 22, September 2012 340/1