Chassis Electrical Control Systems 54.40 Differential Lock Troubleshooting Differential Lock For electrical troubleshooting of the differential lock, see Table 1 . Differential Lock Troubleshooting Symptom Possible Cause Check For Blinking indicator on the differential lock switch. No feedback. Damaged feedback circuit. Axle lock switch is not activated (closed) or is disconnected. Differential lock may engage then drop out, or not engage at all. Insufficient air pressure. If air pressure gauge indicates sufficient pressure, there may be a kink or restriction in the air lines. Defective air management unit (AMU)/auxiliary air valve assembly (AAVA) solenoid.
Remove the air line from the differential housing and turn on the switch. If no air, replace the solenoid. Wiring fault in the axle position feedback circuit. A ground signal from axle switch circuit indicates that the differential lock is activated. Make sure that the axle switch circuit is not shorted to ground. Defective electrical connection to the AMU/AAVA solenoid. Inspect connector and pins. Straighten bent pins and make sure that electrical connections are properly seated. The ground to solenoid or pressure switch circuit is defective. Inspect grounds. Clean or repair as needed.
Table 1, Differential Lock Troubleshooting Business Class M2 Workshop Manual, Supplement 22, September 2012 350/1