Cab Air Suspension 60.14 Height-Control Valve Checking Height-Control Valve Checking are no serviceable parts in the valve, and any disassembly will void the warranty. It is normal to hear air leaking from the height-control valve for as much as five minutes after getting out of the vehicle. This air leakage, due to a decreased load on the cab suspension, is just the height-control valve exhausting air from the air spring to reach the neutral position. Checking the Height-Control Valve Without Using a Test Kit WARNING The height-control valves used on the M2 are Barks- dale valves. Two methods are available to check the operation of the Barksdale height-control valves.
A leak in the valve may be discovered without using a test kit, but a test kit is necessary to determine if the valve has an unacceptable rate of leakage. Keep your hands and all objects away from the area under and around the cab when removing the pressure from the air system. Parts will move as the air is released and can cause personal in- jury or damage to any objects that are between the moving parts. Some Barksdale height-control valves have been re- turned for warranty because the four bolts in the valve housing were overtightened, often, enough to crack the valve housing.
These bolts should not be loose, and should not normally require tightening, as there are no serviceable parts in the valve. 1. With the vehicle parked on a level surface, run the engine to build vehicle air pressure to at least 100 psi (690 kPa), then shut off the engine, apply the parking brakes, and chock the tires. 2. After shutting off the engine, wait 5 to 10 minutes for the air suspension system to equalize. NOTE: Normal operation of the height-control valve requires a maximum of 10 minutes to settle. Any air leakage during this time is consid- ered normal, and does not indicate a defective valve. IMPORTANT:
To prevent voiding the warranty on Barksdale height-control valves, note the fol- lowing: Do not overtighten the bolts in the Barks- dale height-control valve housing if you detect leaks in the housing. The bolts should not be loose, and should not re- quire tightening. Only if necessary, tighten the valve housing bolts 45 lbf·in (500 N·cm). Any damage to the valve housing will void the warranty. 3. Disconnect the vertical linkage from the horizon- tal control lever. 4. Pull the control lever up about 45 degrees for 6 to 8 seconds. If air passes through the valve, that section of the valve is okay.
If it is necessary to remove a Barksdale height-control valve from a mounting bracket, always hold the valve-side mount- ing studs in place with an Allen wrench while loosening or tightening the nuts that attach the valve to the bracket. Because the mounting studs are threaded into the valve body, loosening the nuts without holding the studs can tighten the studs, crushing the valve body and damaging the valve. Conversely, tightening the nuts with- out holding the studs can back the studs out, causing a separation of the two halves of the valve body, and possibly a leak. 5. Return the control lever to the neutral position. 6. Push the control lever down about 45 degrees for 6 to 8 seconds.
If the air spring inflates, that section of the valve is okay. 7. Return the control lever to the neutral position. If the air stops again in the neutral position, the valve is working correctly. 8. If the valve works as stated in all of the above steps, no further checking is needed. Connect the vertical linkage to the control lever, then tighten the linkage nut. NOTE: If a leak is detected, go to "Checking the Height-Control Valve Using a Test Kit." Barks- dale valves have an acceptable leakage rate of 3 cubic inches (50 cc) per minute. You can de- Do not attempt to disassemble the Barks- dale valve body or the control lever.
There Business Class M2 Workshop Manual, Supplement 14, September 2008 110/1