Freightliner — Freightliner Business Class M2 Workshop Manual

Cab Air Suspension 60.14 Height-Control Valve Checking termine if a leak is acceptable only by using the Barksdale test kit. 8. If a flapper is present on the exhaust port of the height-control valve, remove it using needlenose pliers. 9. Remove the chocks. Checking the Height-Control Valve Using a Test Kit 9. Clean the surface around the exhaust port, then install the test fitting into the exhaust port. The centering pin on the fitting must align with the slot on the exhaust port. Rotate the test fitting 45 degrees clockwise to lock it in place; see Fig. 1 . WARNING 10. Connect one end of the air hose from the kit to the test connector on the exhaust port, and the other end to the test gauge.

Keep your hands and all objects away from the area under and around the cab when removing the pressure from the air system. Parts will move as the air is released and can cause personal in- jury or damage to any objects that are between the moving parts. 11. Check the height-control valve in the fill mode, as follows. 11.1 Rotate the valve control lever down 45 degrees from the horizontal to the fill posi- tion. NOTE: The Barksdale field test kit is designed to be used with the height-control valve installed on the vehicle. 11.2 Press the reset button on the test gauge. NOTE: Refer to Specifications 400 for informa- tion on ordering this Barksdale height-control valve test kit.

11.3 Observe the test gauge for 30 seconds. Refer to Fig. 2 for the maximum allowable exhaust pressure change versus inlet pressure. The valve is not working correctly if the gauge pressure reading exceeds the maximum allowable within 30 seconds. 1. If not already done, park the vehicle on a level surface, apply the parking brakes, and chock the tires. 2. Run the engine to build vehicle air pressure to at least 100 psi (690 kPa). If the gauge reads less than the maximum allowable pressure change in 30 seconds, the valve is okay. NOTE: The test gauge will register the exhaust- ing air. This does not indicate a defective valve. 3.

Shut off the engine and wait 5 to 10 minutes for the air suspension system to equalize. NOTE: Normal operation of the height-control valve requires a maximum of 10 minutes to settle. Any air leakage during this time is consid- ered normal, and does not indicate a defective valve. 12. Check the height-control valve in the exhaust mode, as follows. 12.1 Rotate the valve control lever up 45 de- grees from the horizontal to the exhaust position. 4. Check the rubber exhaust flapper at the back of the valve housing for leaks. Use a soapy solu- tion. 12.2 Press the reset button on the test gauge. 5. Disconnect the vertical linkage from the control lever. 12.3 Observe the test gauge for 30 seconds.

Refer to Fig. 2 for the maximum allowable exhaust pressure change versus inlet pressure. 6. Rotate and hold the control lever up at about 45 degrees to exhaust air from the air springs. The valve is not working correctly if the gauge pressure reading exceeds the maximum allowable within 30 seconds. 7. Disconnect the air lines from the air spring ports on the height-control valve. Leave the elbow fit- tings (if equipped) in place. Install a Parker plug into each air spring port (or elbow fitting); see Fig. 1 . Business Class M2 Workshop Manual, Supplement 14, September 2008 110/2