Cab Air Suspension 60.14 Height-Control Valve Checking 7 1 2 3 A 2 1 4 B 6 5 10/08/2007 f321105 A. Exhaust B. Fill 1. Air Spring Port 2. Parker Plug 3. Air Intake Port 4. Exhaust Port Test Fitting 5. Air Line 6. Reset Button 7. Test Gauge Assembly Fig. 1, Test Connections If the gauge reads less than the maximum allowable pressure change in 30 seconds, the valve is okay. PSI MAXIMUM ALLOWANCE EXHAUST PRESSURE CHANGE 25 NOTE: The test gauge will register the exhaust- ing air. This does not indicate a defective valve. 20 13. Disconnect the test gauge and connector from the valve exhaust port. 14. If the height-control valve is defective, replace it; see Subject 120 . 15 15.
Install the flapper on the exhaust port by press- ing it into place. 90 100 110 120 130 INLET PRESSURE 16. Remove the two Parker plugs from the air spring ports, and connect the air lines to the air spring ports (or elbow fittings). Connect the vertical link- age to the height-control valve control lever. The ride height will automatically return to the correct position. f321039a 06/22/2007 Fig. 2, Inlet Pressure vs. Exhaust Pressure Change in 30 Seconds 17. Remove the chocks. Business Class M2 Workshop Manual, Supplement 14, September 2008 110/3