Freightliner — Freightliner Business Class M2 Workshop Manual

Cab Air Suspension 60.14 Air Spring Replacement Replacement 1. With the vehicle parked on a level surface, apply the parking brakes and chock the tires. WARNING Do not disconnect any air lines in the cab sus- pension system without first blocking the cab securely. If the cab isn’t securely blocked, dis- connecting an air line could cause the cab to fall abruptly, possibly resulting in serious injury. 2. Place blocks between the frame and the bottom of the cab, or use jack stands to keep the cab in position when the air spring is deflated. 3. Drain all air from the air tanks. WARNING 01/27/2005 f602205 1. Height-Control Valve 2. Vertical Linkage 3. Air Spring 4. Shock Absorber 5.

Horizontal Control Lever Air lines under pressure can whip dangerously if disconnected under pressure. Drain all air from the air tanks before disconnecting air lines. Dis- connecting pressurized air lines can cause per- sonal injury and/or property damage. Fig. 1, Cab Height-Control Valve is not pushed all the way in, the connection will leak air. Tug on the air line to seat it completely. 4. Remove the nut and washer that attach the verti- cal linkage to the horizontal control lever. Discon- nect the vertical linkage from the control lever; see Fig. 1 . 10. Align the vertical linkage with the control lever and install the washer and nut. 11.

Start the engine, and run it until air pressure builds to at least 100 psi (690 kPa). Check for air leaks at the air spring. 5. Rotate and hold the horizontal control lever up until all air is exhausted from the air spring. 6. Disconnect the supply air tubing from the bottom of the air spring. Push in the brass ring at the connection, then pull the air line straight out. If the new air spring will not be installed immedi- ately, cover the open end of the air tubing to pre- vent dirt or other foreign material from entering. 12. Remove the cab supports. 13. Remove the chocks. 7.

Insert a screwdriver between the upper bracket and the air spring, and pry the air spring away from the bracket to pop the air spring tangs out of the bracket. Repeat the procedure for the bot- tom of the air spring, then pull the air spring out enough to access the supply air tubing. 8. Install the new air spring by snapping it into the bottom bracket first, then the top bracket. 9. Remove the cover from the air line, then connect it by pushing it into the fitting on the bottom of the air spring. Push the air line all the way in. If it Business Class M2 Workshop Manual, Supplement 14, September 2008 140/1 2 1 5 3 4