Freightliner — Freightliner Business Class M2 Workshop Manual

Doors 72.00 Troubleshooting Window Regulator window load, and amount of use, the protection may trip after two or three window cycles. This is normal and is not considered to be a defect. Allow the motor to cool at least 10 minutes to reset the thermal protection before testing. To field test a power window regulator, follow the pro- cedure in Table 1 . NOTE: Power window regulators are equipped with automatic reset internal thermal protection to prevent motor damage from electrical failure or overuse. Depending on the air temperature, To field test a manual window regulator, follow the procedure in Table 2 .

Power Window Regulator Not Working Step Test Procedure Test Result Action 1 Check the fuse for the window regulators. Is it open? Yes Replace the fuse. Continue troubleshooting for a short in the system. 2 Check the battery. Is it fully charged? Yes Go to step 3 . No Go to step 2 . No Charge the battery. 3 Remove the interior door panel. Check for battery voltage at the window regulator terminals. With the window rocker switch in the neutral position, connect a voltmeter to the two terminals where the wiring harness connects to the window regulator motor. A shorted switch may have caused the internal circuit protection in the motor to trip.

Correct the problem, allow the motor to cool for 10 minutes, then check for voltage again. Yes Is voltage present? No Go to step 4 . 4 With the window rocker switch pushed to the "DOWN" position, check the voltage at the regulator terminals. Also check the voltage with the rocker switch pushed to the "UP" position. 11–15 volts Go to step 5 . Below 11 or above 15 volts Check the battery for a full charge, then check the rocker switch for excessive resistance. Repair or replace the switch as needed. What is the voltage reading? No voltage Check the rocker switch for proper function. Replace as needed. 5 Remove the screws that attach the glass to the regulator. Yes Go to step 6 .

Is the glass free to move up and down within the run channels without binding? No Adjust the glass run channels, or correct the binding condition. Go to step 6 . 6 Attach the glass to the regulator, leaving the screws loose so that the glass is free to move slightly from side to side. Test the regulator. Yes Check the regulator mounting alignment, adjust if needed, then tighten the screws. Repeat as necessary. Does the regulator work properly with the glass mounting screws loosened? No Go to step 7 . 7 Test the regulator operation. Does it work properly? Yes Troubleshooting is completed. No Replace the window regulator.

Table 1, Power Window Regulator Not Working Business Class M2 Workshop Manual, Supplement 17, March 2010 300/1