Doors 72.00 Troubleshooting Manual Window Regulator Not Working or Noisy, Window Glass Binding Step Test Procedure Test Result Action 1 Remove the interior door panel to gain access to the window regulator. 2 Are the regulator mounting screws tight, and is the glass secured to the regulator. Yes Go to step 3 . 3 Disconnect the glass from the regulator. No Correct any problems and retest. Check that the glass attachment point of the regulator moves when the handle is cranked. If it does not, replace the regulator. Otherwise, go to step 4 . Is the glass free to move up and down within the run channels without binding? Yes No Adjust the glass run channels, or correct the binding condition.
Go to step 4 . 4 Connect the glass to the regulator, leaving the screws loose so that the glass is free to move slightly from side to side. Crank the handle. Yes Raise and lower the glass completely, then tighten the glass mounting screws. Loosen the regulator mounting screws and try to adjust the regulator alignment for proper operation. The glass also may need to realigned after any adjustments to the regulator. Does the regulator work properly with the glass mounting screws loosened? No 5 Test the regulator operation. Does it work properly? Yes Troubleshooting is completed. No Replace the window regulator.
Table 2, Manual Window Regulator Not Working or Noisy, Window Glass Binding Business Class M2 Workshop Manual, Supplement 17, March 2010 300/2