Freightliner — Freightliner Business Class M2 Workshop Manual

Cab Heater and Air Conditioner, Valeo 83.00 General Information 1 (2070 kPa ±70 kPa). The fan turns off when the pressure drops below 250 ±10 psi (1725 kPa ±70 kPa). 2 Heater Core 3 3 The heater core is a convoluted tube covered with fins. When the water valve is open, warm engine coolant flows through the heater core tube, heating the tube and fins. The blower motor blows air through the finned tube and into the cab, to heat the cab. Receiver-Drier E A 3 3 D B The receiver-drier is a reservoir and filter for liquid refrigerant. It also removes water and acids from the refrigerant.

The water-absorbing material (desiccant) in the unit helps stop blockages caused by moisture forming in the expansion valve and other parts of the system. Refrigerant C 4 02/28/94 f830045b 5 A. To the compressor B. From the receiver-drier C. Bleed at the ball seat D. To the evaporator E. From the evaporator Refrigerant is the chemical that absorbs heat from the air in the cab and release it to the air outside the cab. 1. Internal Equalization Passage 2. Temperature Sensor 3. O-Ring 4. Metering Orifice 5.

Ball and Spring During compressor operation, refrigerant constantly changes from a gas to a liquid, then back to a gas, depending on whether it is absorbing heat (boiling) in the low pressure evaporator, or releasing absorbed heat in the high pressure condenser. Refrigerant Compressor Fig. 2, Expansion Valve The expansion valve proportions the flow rate of re- frigerant according to the rate of evaporation in the evaporator. If the amount of liquid in the evaporator drops off, the temperature of the gas going to the compressor rises. This causes a sensor tube in the expansion valve to react to the temperature changes, which causes an orifice in the valve to open or close.

Through the orifice, liquid refrigerant is metered into the evaporator. Fan Cycling Switch "Heat" in the low pressure gas of the evaporator does not feel warm to the touch, because liquid re- frigerant boils at a temperature much lower than the temperature at which water turns to ice. By touch, the "heated" gas in the coils is very cold. As a result, there is the problem of how to remove heat from subfreezing gas using outside air that may be higher than 100°F (38°C). With a refrigerant compressor, low pressure gas from the evaporator can be squeezed into a much smaller space. When the gas is compressed, the heat it con- tains becomes concentrated.

In this way, the gas is made hotter than the outside air without adding heat. Located on the receiver-drier, the fan cycling switch sends a ground signal to the ECM (electronic control module) to keep the fan turned off, and takes away the ground to engage the fan. The fan will come on if the refrigerant pressure is greater than 300 ±10 psi If the system pressure rises above 550 ± 50 psi (3792 ± 345 kPa), a pressure relief valve will vent, Business Class M2 Workshop Manual, Supplement 18, September 2010 050/4