Freightliner — Freightliner Business Class M2 Workshop Manual

Cab Heater and Air Conditioner, Valeo 83.00 Receiver-Drier Replacement Replacement IMPORTANT: If the desiccant cartridge inside the receiver-drier has fallen apart, flush the sys- tem and replace the expansion valve and the refrigerant compressor (desiccant matter can’t be removed from these parts). A cartridge may fall apart from too much moisture in the system, because of poor evacuation of the system, or lack of maintenance. 1. Turn off the engine, apply the brakes, and chock the tires. 2. Open the hood. 3. Recover the refrigerant from the air conditioning system. For instructions, see Subject 220 . 4.

Disconnect the wiring harness from the fan cy- cling switch and disconnect the wiring harness from the binary switch. See Fig. 1 . 8. Using U-bolts, mounting brackets, nuts, and washers, install a new receiver-drier on the frame rail. 9. Uncap the refrigerant lines. 10. Using only Mini Stat-O-Seals, replace the Mini Stat-O-Seals on the refrigerant lines. Do not lu- bricate Mini Stat-O-Seals prior to installation. 1 2 3 11. Connect the refrigerant lines to the receiver-drier. Torque the bolt on the retaining plate 11 to 15 lbf·ft (15 to 20 N·m). 12. Attach the fan cycling switch and the binary switch to the receiver-drier. 13.

Attach the fan cycling wiring harness to the fan cycling switch and attach the binary switch wiring harness to the binary switch. 14. Evacuate and charge the air conditioning system with refrigerant. For instructions, see Sub- ject 220 . 4 12/21/2001 f543878 15. Be sure to add refrigerant oil to the compressor to replace that which is lost when the system is recovered. See Section 83.01 , Subject 130. 1. Fan Cycling Switch 2. Moisture Indicator 3. Binary Switch 4. Receiver-Drier Fig. 1, Receiver-Drier 16. Return the hood to the operating position. 5. Remove the fan cycling switch and the binary switch from the receiver-drier. 17. Remove the chocks from the tires. 6.

Disconnect the refrigerant lines from the receiver-drier. Quickly cap the refrigerant lines. IMPORTANT: Under no circumstances should the refrigerant lines remain uncapped for longer than five minutes. Water and dirt can damage the refrigerant system. Do not blow shop air through refrigerant lines since shop air is wet (humid). 7. Remove the nuts and washers that attach the U-bolts and mounting brackets to the frame rail. Remove the receiver-drier. Business Class M2 Workshop Manual, Supplement 0, January 2002 180/1