Cab Heater and Air Conditioner, Valeo 83.00 Refrigerant Service Operations Required Equipment 1. Using a high-quality refrigerant identifier and the manufacturer’s instructions, attach the identifier to the vehicle and perform the test. You will need a machine, or machines, to identify the refrigerant and to recover, evacuate, flush, and charge the refrigerant system. Ideally, it will be a single machine able to perform all the following func- tions: 2. If the vehicle passes the test, it is safe to recover the refrigerant. 3. If the vehicle fails the test due to an excessive amount of noncondensable gas, recover the re- frigerant system, then purge the recovery tank of the noncondensable gas.
Identification—The machine must be able to verify the purity of the refrigerant in the air con- ditioning system, and should test for the pres- ence of unapproved refrigerants. 4. If the test revealed the presence of a hydrocarbon-based refrigerant or a refrigerant other than R-134a, do not recover the refriger- ant into the general-use machine. Recover non-R-134a refrigerant into a separate container specifically for refrigerant that must be recycled by a qualified recycling center. It is best to refer the customer to the place where the vehicle was last serviced, since properly disposing of non- 134a refrigerants can be difficult and expensive.
Recovery—The machine must be able to re- cover all traces of refrigerant from the air con- ditioning system. Evacuation—Ideally, the machine should have a vacuum pump rated at 6 cfm, and be mainte- nance free. A machine that requires mainte- nance is acceptable as long as it is properly maintained. Charging—The scale used in charging should be accurate to within ±1 ounce (30 mL). Recovery Flushing—Adaptors for the compressor(s), ex- pansion device(s), and receiver-drier should be purchased or fabricated, to flush the system with refrigerant. The recovery process removes most of the refriger- ant charge in the system. 1.
Turn off the engine, apply the parking brakes, chock the tires, and open the hood. Refrigerant Identification 2. Remove the caps from the suction and discharge service valves. WARNING 3. If the history of refrigerant system repairs is un- known, or if you suspect that the system is charged with an unapproved refrigerant, identify the refrigerant using the "Refrigerant Identifica- tion" procedures. Before doing any of the work below, read the in- formation in Safety Precautions 100 . Failure to read and understand the safety precautions, and to take necessary precautions against the dan- gers involved when working with refrigerant, could lead to serious personal injury. 4.
Wearing protective goggles and nonleather gloves, attach the refrigerant recovery and charg- ing machine hoses to the valves. IMPORTANT: Push down firmly on the hose connectors, until they click into engagement. This ensures that the coupler is locked. IMPORTANT: Identify the specific type of refrig- erant in the air conditioning system, if you sus- pect one of the following possibilities: Excess noncondensable gas, such as ni- trogen or air, is in the system. 5. Follow the refrigerant recovery and charging ma- chine manufacturer’s instructions, and recover all of the refrigerant from the refrigerant system. IMPORTANT:
Always comply with all federal and local regulations regarding refrigerant recovery and disposal. You may be subject to substantial penalties for improper procedures. An unapproved refrigerant is in the sys- tem. The history of refrigerant system repairs is unknown. Business Class M2 Workshop Manual, Supplement 20, September 2011 220/1