Freightliner — Freightliner Business Class M2 Workshop Manual

Cab Heater and Air Conditioner, Valeo 83.00 Refrigerant Service Operations amount of refrigerant oil. Replace the receiver- drier if the system conditions require it. Flush the system in segments to lessen the chance of blowing deposits against a port. 2. Make sure the vacuum pump has been properly maintained. Flush the system in the opposite direction of refriger- ant flow. In other words, backflush the sections. 3. Wearing protective goggles and nonleather gloves, attach the refrigerant recovery and charg- ing machine hoses, or a vacuum pump, to the valves. IMPORTANT: Push firmly on hose connectors until they click into engagement. This ensures that they are locked.

Flushing parts with refrigerant requires a refrigerant recovery and charging machine. Flushing Procedure Method 1 NOTE: Use this method when the recovery and charging machine is equipped with a flush cycle. 4. Follow the refrigerant recovery and charging ma- chine manufacturer’s instructions, and evacuate the refrigerant system. 1. Recover the refrigerant from the air conditioning system. 5. A minimum of 10 minutes with a 6-cfm pump should be used to evacuate the system, but a smaller pump requires a longer evacuation time. Make sure that the vacuum level reaches and maintains a point where water boils at your ambi- ent temperature, then proceed with charging and leak testing the system. 2.

Disconnect both ends of the line or part(s) being flushed. Tightly cap the lines to the rest of the system. NOTE: You must remove the expansion de- vice(s), receiver-drier, and compressor(s) when flushing. These components must be removed and bypassed when performing a system flush. Flushing 3. Install the flushing adaptors and an inline filter and follow the instructions from the manufacturer of the recovery and charging machine to perform the flush. When flushing the entire system, use an adaptor that fits where the compressor was located and backflush. Flushing removes moisture-laden oil and some con- tamination, such as dirty oil and some particles.

When a part is flushed, liquid refrigerant is forced through it. The liquid picks up the contaminants and flushes them out. 4. Remove the adaptors and bypass devices and install the expansion device(s), the compressor, and a new receiver-drier. Whether to flush or replace a part depends on how much contamination there is as previously described. Normally, the system always has pressure in it. Some loss of refrigerant from one season to the next is normal, and does not mean that the system is dirty. If refrigerant parts show signs of internal corro- sion and grit, the system is contaminated. 5. If installing the existing compressor, remove the oil in it and replace the oil with new oil.

New compressors may or may not have a full charge of oil. 6. Charge the system with refrigerant and check the system performance. Method 2 If the system is contaminated with moisture, flush all sections of the system. Then change the oil in the compressor and replace the receiver-drier prior to evacuating and charging the system. NOTE: Use this method when two recovery and charging machines are available. If the system is heavily contaminated or if desiccant has circulated through the system, replace the receiver-drier, expansion valve(s), and inspect the compressor. 1. Recover the refrigerant from the air conditioning system. Do not flush the receiver-drier or the compressor. 2.

Disconnect both ends of the line or part(s) being flushed. Tightly cap the lines to the rest of the system. Business Class M2 Workshop Manual, Supplement 20, September 2011 220/4