Freightliner — Freightliner Business Class M2 Workshop Manual

Cab Heater and Air Conditioner, Valeo 83.00 Refrigerant Service Operations NOTE: You must remove the expansion de- vice(s), receiver-drier, and compressor(s) when flushing. These components must be removed and bypassed when performing a system flush. to the recovered oil plus the oil coating the in- side of the component must be returned to the system. IMPORTANT: Refrigerant oil is hygroscopic (at- tracts moisture from its surroundings), and must not be exposed to the moisture that is present in the air. New oil must be from a container that has not been opened or that has been tightly sealed since its last use. 3. Install the flushing adaptors and an inline filter.

When flushing the entire system, use an adaptor that fits where the compressor was located and backflush. 4. Charge the part with 2 pounds (0.9 kg) of refrig- erant or the system with 5 pounds (2.3 kg) of refrigerant, then recover the refrigerant with a second machine. It is desirable to start the re- covery slightly before the charge cycle is done since this helps to push fluid through the system. Repeat the process several times until you think that all the oil has been removed. Tubing, funnels, or other equipment used to transfer the oil must be very clean and dry. When handling refrigerant oil:

Be sure that the oil is free of water, dust, metal powder, and other foreign substances; Do not mix the refrigerant oil with other types or viscosities of oil; 5. Remove the adaptors and bypass devices and install the expansion device(s), the compres- sor(s), and a new receiver-drier. Quickly seal the oil container after use. Refrig- erant oil absorbs moisture when exposed to the air for any period of time. Compressor Oil Balancing 6. If installing the existing compressor, remove the oil in it and replace the oil with new oil. New compressors may or may not have a full charge of oil. 7. Charge the system with refrigerant and check the system performance.

Replacement refrigerant compressors are supplied with some refrigerant oil. If the air conditioning sys- tem has been flushed, the system will need a com- plete new charge of oil. If the system has not been flushed, use the following procedures to adjust the oil level, when a new compressor or other system com- ponent has been installed. The type of oil required depends on the brand of compressor used on the system. Refer to the workshop manual for the spe- cific compressor on the vehicle being serviced for details about how the total system volume is deter- mined. See PartsPro MOD 700 to determine the oil type and vehicle specific oil quantities.

Oil Balancing General Information Compressors require refrigerant oil to function. When the air conditioning system is operating, some of the oil leaves the compressor and is circulated through the system with the refrigerant. The refrigerant oil cannot leave the system except when there is a leak, the refrigerant is recovered, or when a system part is replaced. It is important that the air conditioning sys- tem has the correct amount of refrigerant oil for proper operation. Too little oil will result in compres- sor failure. Too much oil will degrade the perfor- mance of the air conditioner, and cause damage to the compressor. IMPORTANT:

Whenever the air conditioning system is discharged or recovered, the recov- ered oil, from the charging machine, must be measured in order to know how much oil must be returned to the system. When a system com- ponent is replaced, a quantity of new oil equal 1. Drain the remaining oil from the compressor into a clean graduated container, and note the amount. See Fig. 2 . 2. Make note of the total volume of oil recovered. 3. Drain the oil from new compressor into a clean calibrated container, and compare the two quan- tities of oil. 4. Add only the amount of oil removed during re- covery and from the old compressor to the sys- tem.

Business Class M2 Workshop Manual, Supplement 20, September 2011 220/5