Cab Heater and Air Conditioner, Valeo 83.00 Refrigerant Service Operations Refrigerant Oil Quantities for Replaced Components Add the quantities listed in this table for each component that was replaced. Use the sum of the quantities or 6 floz (177 mL), whichever is less. Component Quantity oz (mL) 1 2 Low Pressure Line (auxiliary A/C) 3 (89) (A−B) Condenser 1 (30) Evaporator (main A/C) 3 (89) Evaporator (auxiliary A/C) 2 (59) A B Receiver-Drier 3 (89) Minor Leak at Connector Only 0.5 (15) Major Leak at Connector Only 2 (59) 11/18/2009 f831837 1. New Compressor 2 Old Compressor Table 2, Refrigerant Oil Quantities for Replaced Components Fig. 2, Oil Balancing 5.
Add the new compressor oil as described in the supplier specific compressor service section of the workshop manual. System Oil Balancing Charging NOTE: Before charging, the system must be recovered and evacuated with the recovery and charging machine connected to the service and discharge port connections. After repairs are finished, refer to Table 2 and use the following equation to determine the quantity of refrigerant oil that needs to be added to the system. 1. Obtain enough refrigerant to fully charge the sys- tem. To determine the amount of refrigerant needed to fully charge the system, read the Air Conditioner label on the vehicle or see Specifi- cations 400 .
[Quantity Recovered] + [Quantity for All Replaced Components ] = [Quantity Added to the System] Table 2 provides the quantities of oil that need to be added to the system for each component that was replaced. Add the quantities listed in the table for each component that was replaced. Use the sum of the quantities or 6 floz (177 mL), whichever is less. Inject the calculated oil volume at the high-side pres- sure port during the refrigerant charging process. 2. Charge the system on the high side following the refrigerant recovery and charging machine manu- facturer’s instructions. 3.
While the compressor is engaged, check the duct temperature and operating pressures at the suction and discharge ports. Compare the tem- perature and pressures to those in Specifica- tions 400 . If the operating pressures are not ac- ceptable, see Subject 300 for troubleshooting procedures. Refrigerant Oil Quantities for Replaced Components Add the quantities listed in this table for each component that was replaced. Use the sum of the quantities or 6 floz (177 mL), whichever is less. 4. Disconnect the hoses. Component Quantity oz (mL) 5. Shut down the engine. High Pressure Line (main A/C) 1 (30) 6. Recover the refrigerant that is in the hoses.
Low Pressure Line (main A/C) 2 (59) High Pressure Line (auxiliary A/C) 1 (30) Business Class M2 Workshop Manual, Supplement 20, September 2011 220/6