Cab Heater and Air Conditioner, Valeo 83.00 Refrigerant Service Operations Electronic Leak Detectors Designation Manufacturer Comments Leybold Inficon 2 Technology Place Rechargeable battery D-TEK, D-Tek Select, and TekMate East Syracuse NY 13057 Hand-held design (315) 434–1144 Simple to operate Bacharach Inc. c/o Yokogawa Corp.
of America Rechargeable battery H–10 Professional 2 Dart Road Carrying case with strap Calibration leak bottle Newnan GA 30265 Manual sensitivity control (800) 850–0044 Most sensitive available SPX Kent-Moore 12V DC or 120V AC J 39400 28635 Mound Road Carrying case with strap Calibration leak bottle Warren MI 48092–3499 Manual sensitivity control (800) 328–6657 Manual balance control Table 4, Electronic Leak Detectors 5. Visually inspect the entire refrigerant system. Look for air conditioning lubricant leakage, and corrosion or damage to lines, hoses, and all other components. Inspect each questionable location carefully with the detector probe.
Check all fittings, couplings, refrigerant controls, service ports (with caps installed), brazed or welded areas, and areas around attachment points and hold-downs. area and repeating the inspection. Pinpoint a large leak by blowing out the area often. 9. You may test the evaporator core with it in its housing. Turn on the blower motor for a mini- mum of 15 seconds. Shut off the blower and wait for refrigerant gas to accumulate in the housing. Follow the detector instructions for the specific length of time to wait for the gas to accumulate. Insert the detector probe into the blower resistor block, or condensate drain tube if no water is present.
If this is not possible, insert the probe into the closest opening to the evaporator, such as a heater or vent duct. NOTE: Water inside the condensate drain tube can be removed by inserting a pencil-size rod into the drain tube. Inserting the rod will break the surface tension of any water near the open- ing of the drain tube, and allow the water to drain out so the probe tip can get an accurate reading. It is only necessary to break the plane of the drain tube with the probe tip, it does not need to be inserted far into the tube. 6. Follow the path of the refrigerant system me- thodically, so that no leaks are missed. If a leak is found, continue to test the rest of the system. 7.
Inspect an area of possible leakage slowly and close to the part, moving completely around the part. Move the probe no faster than one to two inches (25 to 50 mm) per second and no farther away than 1/4 inch (6.4 mm) from the part. 8. If a large leak is present in either the system being serviced or the service equipment, the sur- rounding air will be saturated with refrigerant gas. In this situation the leak detector gives er- ratic readings and will indicate leakage without being near a possible leak source. Place a large fan so that a light breeze blows through the work area. Verify a leak by blowing shop air into the 10. Leak test the front seal area of the compressor.
Blow shop air into the cavities in and around the clutch, for at least 15 seconds. Let the compres- Business Class M2 Workshop Manual, Supplement 20, September 2011 220/9