Freightliner — Freightliner Business Class M2 Workshop Manual

Cab Heater and Air Conditioner, Valeo 83.00 Troubleshooting Problem Low-Side Pressure Too Low Possible Cause Remedy There are line or component restrictions. Remove the restrictions. The refrigerant charge is low. Perform a leak test. Repair any leaks, evacuate the system, replace the receiver-drier, and add a full refrigerant charge. Problem High-Side Pressure Too High Problem High-Side Pressure Too High Possible Cause Remedy Airflow through the condenser is restricted. Check for and remove dirt or debris in front of the condenser and radiator. Check the engine fan operation.

There is an internal restriction in the condenser indicated by ice buildup on the condenser or a cool spot on the line from the condenser to the receiver-drier. Replace the condenser. If compressor failure recently occurred, the blockage may be due to debris from a failed compressor. Air is in the refrigerant. Perform a leak test. Repair any leaks, evacuate the system, replace the receiver-drier if necessary, and add a full charge of refrigerant. The engine is overheated. Check the engine cooling system. Restriction in the compressor discharge line. Replace the line.

Problem Compressor Runs Continuously Problem Compressor Runs Continuously Possible Cause Remedy Low refrigerant charge in the system. Perform a leak test. Repair any leaks, evacuate the system, replace the receiver-drier, and add a full charge of refrigerant. The evaporator probe isn’t working. Refer to "Evaporator Probe Circuit Tests" for diagnosis. Problem Little or No Heat Problem Little or No Heat Possible Cause Remedy Low engine coolant. Check coolant level. If low, check for source of leak and repair as necessary. Plugged heater core. Flush or replace the heater core as necessary. Engine thermostat is not working. Check to see if the engine thermostat is stuck open.

Refer to Section 20.00, Subject 300 for diagnosis. Engine fan on all the time. Refer to Group 20 for diagnosis. Mechanical problem with temperature blend door actuator. Inspect the temperature blend door actuator for obstructions or mechanical damage. Correct as necessary. Problem with the wiring. Refer to "Temperature Blend Door Actuator Circuit Tests" for diagnosis. The control head is not working. Business Class M2 Workshop Manual, Supplement 13, March 2008 300/5