Cab Heater and Air Conditioner, Valeo 83.00 Troubleshooting System Troubleshooting Tables Problem No Fresh Air (nonrecirculation mode) Problem No Fresh Air (nonrecirculation mode) Mechanical problem with the recirculation door actuator. Inspect the recirculation door actuator for obstructions or mechanical damage. Correct as necessary. Possible Cause Remedy Problem with the wiring. Refer to "Recirculation Door Actuator Circuit Tests" for diagnosis. The control head is not working. The blower motor is in protection mode. Refer to "Blower Motor Circuit Tests" for diagnosis.
Problem Warm Airflow When the Air Conditioner is On; A/C is Not Working; or Poor Performance of A/C Problem Warm Airflow When the Air Conditioner is On; A/C is Not Working; or Poor Performance of A/C Possible Cause Remedy Low refrigerant charge in the system. Perform a leak test. Repair any leaks, evacuate the system, replace the receiver-drier, and add a full charge of refrigerant. Too much refrigerant in the system. Evacuate the system, then add a full charge of refrigerant. Moisture in the system. If moisture is in the system, ice crystals may form and block the flow of refrigerant at the expansion valve or other places in the system.
Recover the refrigerant, replace the receiver-drier, evacuate the system, and add a full charge of refrigerant. The refrigerant compressor is not working. The refrigerant charge is low or high. The refrigerant compressor clutch or drive belt needs repair or replacement. Refer to "A/C Clutch Circuit Tests for Diagnosing No A/C Clutch Engagement" in this subject. Ice has formed on the evaporator coil. Defrost the evaporator coil before resuming operation of the air conditioner. Refer to "Evaporator Probe Circuit Tests" in this subject for diagnosis. Temperature blend door actuator is not working. Refer to "Temperature Blend Door Circuit Tests" in this subject for diagnosis.
Mechanical problem with temperature blend door actuator. Blockage in A/C system such as lines, evaporator, condenser, or expansion valve. Remove the blockage. The blower motor is in protection mode. Refer to "Blower Motor Circuit Tests" for diagnosis. The evaporator probe isn’t working or is out of range. Refer to "Evaporator Probe Circuit Tests" for diagnosis. Problem Low-Side Pressure Too Low Problem Low-Side Pressure Too Low The expansion valve is not working. Check the expansion valve for blockage and function. Blockage may be due to moisture causing ice formation. Possible Cause Remedy Business Class M2 Workshop Manual, Supplement 13, March 2008 300/4