Refrigerant Compressor, Sanden 83.01 Oil Check and Adding Oil to the Compressor Refrigerant Oil Quantities for Replaced Components Add the quantities listed in this table for each component that was replaced. Use the sum of the quantities or 6 floz (177 mL), whichever is less. Component Quantity: oz (mL) High Pressure Line (main A/C) 1 (30) Low Pressure Line (main A/C) 2 (59) High Pressure Line (auxiliary A/C) 1 (30) Low Pressure Line (auxiliary A/C) 3 (89) Condenser 1 (30) Evaporator (main A/C) 3 (89) Evaporator (auxiliary A/C) 2 (59) Receiver-Drier 3 (89) Minor Leak at Connector Only 0.5 (15) Major Leak at Connector Only 2 (59) Table 1, Refrigerant Oil Quantities for Replaced Components 7.
Remove the oil fill plug on the refrigerant com- pressor and add the refrigerant oil. Never add more than 8 floz (237 mL) to the system unless the system has been flushed. 8. Evacuate, charge, and leak test the refrigerant system. See Section 83.00, Subject 220 for in- structions. Adjusting the Refrigerant Oil Level in a New Compressor Sanden refrigerant compressors are charged with 10 floz (296 mL) of refrigerant oil. If the air conditioning system has been flushed, the compressor will need a 10-ounce charge. If the system has not been flushed, use the following procedure to adjust the oil level in the compressor.
Use the "Worksheet for Adjusting the Refrigerant Oil Level in a New Compressor" shown in Fig. 1 to ad- just the refrigerant oil level in a new compressor. Business Class M2 Workshop Manual, Supplement 13, March 2008 130/2