Freightliner — Freightliner Business Class M2 Workshop Manual

Hood 88.00 Hood Repair of the crack, to prevent the crack from lengthen- ing. See Fig. 3 . 1 2 3 1 4 A 2 A f880227b 05/04/94 A. Grind a shallow recess one-quarter the depth of the FRP and extending 1/2 inch (13 mm) outward in all directions from the damaged area. 1. FRP 2. Crack 3. Slight Taper 4. Engine Side of Hood (or underside of ) Fig. 4, Recessed Area (cross-sectional view) f880222b 05/04/94 A. 1/8 inch (3 mm) 1. Drilled 1/8-inch (3-mm) Hole 2. End of Crack Fig. 3, Drilling a Hole to Prevent the Crack From Lengthening 5.

On the engine side of the hood (or underside of the ), use a router bit (on a grinder or a drill) to grind away a shallow recess one-quarter the depth of the laminate and extending 1/2 inch (13 mm) outward from all sides of the damage. Taper the outside edge of the ground area. See Fig. 4 . If repairing a crack, grind outward to the drilled hole at the end of the crack, but not beyond. See Fig. 5 , Ref. A. f880223a 02/09/94 A. Use a router to grind away a shallow recess one- quarter the depth of the FRP and extending 1/2 inch (13 mm) outward from the damage. If repairing a crack, don’t grind past the hole drilled at the end of the crack. B.

Use 80- to 220-grit sandpaper to scuff the area 1 inch (25 mm) around the damage. C. Cut the fiberglass cloth to fully cover the damage, and overlay about 3/4 inch (20 mm). 6. Use 80- to 220-grit sandpaper to scuff an area at least 1 inch (25 mm) away from the fracture on all sides. Be sure to scuff thoroughly, since this will give the patch a surface to which it can stick. See Fig. 5 , Ref. B. 7. Blow the dust away with compressed air and wipe the area with a clean cloth. 8. If necessary, align the panel sections on both sides of the crack, using weights or clamps to re-establish the original panel profile. 1. Hole 2. Crack Fig. 5, Preparing the Damaged Area on the Engine Side of the Hood 9.

With a razor-blade knife, cut a section of woven fiberglass cloth to fully cover the crack and to overlay about 3/4 inch (20 mm). See Fig. 5 , Ref. C. 10. To bond the fiberglass cloth to the damaged panel, use Ashland Pliogrip 7775L urethane ad- hesive. Business Class M2 Workshop Manual, Supplement 0, September 200 2 140/3 1 2 A B C