TwinFlow Fire Pump 90.00 General Information Water enters the spinning impeller at the intake and is confined by shrouds and vanes in the impeller, which, in turn, builds pressure. The vanes guide the water away from the inlet to the discharge to reduce the water’s turbulence and to move the water toward the outer edge of the impeller. The shrouds serve as the sides of the impeller and confine the water to the centrifugal acceleration. 1 2 3 4 Single-stage pumps provide the same operating and rating-test pressures as a two-stage pump, but the two-stage pump offers additional operating (water) pressure.
The primary difference between a single-stage and a two-stage pump is that the single-stage has only one impeller and no transfer valve to switch between vol- ume and pressure operation. A transfer valve is a two-position valve that permits the impellers in a two- stage pump to operate in parallel (volume) or series (pressure). f190011 02/04/98 1. Shroud 2. Impeller Eye 3. Shaft 4. Mechanical Seal Housing In two-stage pumps, the volume operation results in the pressure at the pump intake being added to the equal pressure developed by the impellers, and the amount of water sent to the discharge being the sum of the flows of the two impellers.
The pressure op- eration features the impellers operating in series, or the output of the primary impeller supplied from the pump intake is supplied to the input of the secondary impeller. Thus, the pressure at the pump discharge is the sum of the pressures of the two impellers plus the pressure at the intake. The flow is then half of the volume operation. Fig. 2, Fire Pump Gearbox The pump body is split horizontally in two sections for ease of removal of the impeller assembly, includ- ing the bearings and the clearance rings. The pump gearbox and the impeller assembly are removable from the bottom of the vehicle in order to avoid interference with the pump plumbing and con- trol mechanisms.
The pump has two large suction inlets, one on each side of the vehicle, though other inlets may be present. The inlets and the internal pump outlets are on opposite sides of the pump to balance forces caused by the intake and the discharge of water. In both types of pumps, the pressurized water is pre- vented from returning to the intake of the impeller(s) by clearance rings. Centrifugal pumps have clear- ance rings mounted between the spinning impeller and the pump body. Clearance rings, as well as the hubs of the impeller(s), will, over time, become worn or pitted and may need to be replaced, or machined to a smaller diameter.
The AutoLube is built into the pump assembly to con- tinuously force oil to the impeller shaft bushing to lubricate and cool the impeller bushing. Principles of Operation TwinFlow centrifugal pumps operate on the principle of centrifugal force, created by a rapidly spinning disk, (impeller). Water is routed to the center of the impeller, which throws the water outward. When wa- ter is confined in a closed container, in this instance, the pump body, the water pressure increases. The pressure level depends on how fast the impeller is rotating. Business Class M2 Workshop Manual, Supplement 9, March 2006 050/2