TwinFlow Fire Pump 90.00 Valve Removal, Disassembly, Assembly, and Installation 14. Slide the cover into the relief valve body. Then install the cover retaining ring. 7. Remove the retaining ring that secures the relief valve piston to the relief valve. Gently push the relief valve into the pump body approximately 1 inch (25 mm), then pull it back out in a snap- motion. This should pop the relief valve piston out of the relief valve body. Repeat if necessary. 15. Using a powered test light, screw the indicator light switch in until the light goes out. Then turn an additional 3/4 to 1-1/4 turn. Apply Loctite 242 to the jamnut and tighten it. NOTE:
It is not necessary to remove the relief valve unless it is damaged. To remove the relief valve, the relief valve body will have to be re- moved and the complete relief valve assembly will need to be replaced (as it will be necessary to pry the relief valve body from the pump body, which will likely damage it). 16. Slide the relief valve assembly into the pump body with the side marked "top" up, being careful not to damage the O-rings. 17. Apply Loctite 242 to the four 7/16–14 x 1-1/4 capscrews, then install the assembly in the pump body. Tighten the capscrews to 53 lbf·ft (72 N·m). 18. Connect the indicator light switch. 8. Clean and inspect all of the relief valve assembly components. 19.
Fill the pump, then test the valve for proper op- eration and leaks. 9. Clean all sealing surfaces and install new O-rings and Quad-ring seals. QD Relief Valve 10. Install the relief valve piston in the stem of the relief valve. Do not push the relief valve into the pump body. As it is necessary to start the piston on the relief valve stem, push the piston until you can grasp the relief valve stem. Then pull the relief valve stem outward while pushing on the relief valve piston. Once the relief valve piston is seated against the shoulder of the relief valve stem, install the retaining ring. NOTE: For an exploded view of the QD relief valve, see Fig. 2 . 1. Drain the pump. 2.
Note the location of the wires, then disconnect the indicator light switch. 3. Disconnect the relief valve supply line from the pilot valve and drain the line. 11. Operate the relief valve by hand to check for freedom of movement. 4. Remove the two 7/16–14 x 1-1/4 capscrews that attach the relief valve indicator light switch and the mounting bracket assembly to the relief valve cover. Remove the light switch and the bracket. 12. Slide the relief valve cover gasket and cover over the top of the relief valve stem to align the relief valve supply line from the pilot valve in the original position.
Then, apply Loctite ® 242 to two 7/16–14 x 1-1/4 capscrews and install them op- posite of each other. Tighten, but do not torque them. 5. Compress the relief valve return spring (by hand), and remove the E-clip and washer. Then, remove the return spring. 6. Remove the two remaining 7/16–14 x 1-1/4 cap- screws that retain the relief valve cover to the pump body. Using a twisting motion, carefully remove the relief valve cover. 13. Compress and install the return spring, and se- cure it with a washer and E-clip. 14. Align the indicator light switch mounting bracket and switch with the two empty holes in the relief valve cover. Install the two remaining 7/16–14 x 1-1/4 capscrews.
Tighten all capscrews 53 lbf·ft (72 N·m). CAUTION Do not push the relief valve too far into the pump body as it may fall into the pump body and be- come lodged or damaged. The relief valve is made of brass and is easily damaged by prying or hammering. Damaged valves must be re- placed. 15. Connect the relief valve supply line from the pilot valve. Also, connect the drain line. 16. Connect the indicator light switch. Business Class M2 Workshop Manual, Supplement 8, September 2005 150/6