PowerFlow Fire Pump 90.01 General Information water pressure increases. The pressure level de- pends on how fast the impeller is rotating. Water entering the pump intake is routed to the cen- ter of the rapidly spinning impeller, which is confined by the shrouds and vanes in the impeller, which builds pressure. The vanes guide the water away from the inlet to the discharge manifold to reduce the water’s turbulence. The pressurized water is prevented from returning to the intake of the impeller by clearance rings. Cen- trifugal pumps have clearance rings mounted be- tween the spinning impeller and the pump body.
Clearance rings, as well as the hubs of the impeller, will, over time, become worn or pitted and may need to be replaced, or machined to a smaller diameter. Business Class M2 Workshop Manual, Supplement 8, September 2005 050/2