Freightliner — Freightliner Business Class M2 Workshop Manual

PowerFlow Fire Pump 90.01 Mechanical Seal Replacement Replacement CAUTION 4 2 3 DO NOT TOUCH the sealing surfaces of the seal as contamination will result in premature failure. WARNING Many of the components on the fire pump are heavy and awkward to handle. Always use the proper support equipment during removal and installation of the fire pump. Failure to do so could result in an assembly falling which could result in personal injury or property damage. 1 07/13/2001 f190038 1. Mechanical Seal 2. Rear Clearance Ring 3. Impeller Shaft 4. Volute Housing 1. Drain the water from the pump. 2. Park the vehicle on a level surface. Shut down the engine.

Set the parking brake and chock the front and rear tires. Fig. 1, Volute Housing (impeller removed) NOTE: If the clearance rings are not defective, they do not need to be replaced when replacing the mechanical seal. CAUTION The use of any petroleum product to lubricate the mechanical seal will result in damage to the me- chanical seal. 3. Remove the pump impeller. See Subject 120 . NOTE: The mechanical seal is exposed once the impeller is removed. 7. Clean the impeller shaft with a fine Scotchbrite pad. Wipe off the impeller shaft, then lubricate it with a mixture of water and liquid soap. 4. Remove the mechanical seal from the impeller shaft, being careful not to damage the impeller shaft.

See Fig. 1 . NOTE: If the oil seal in the volute housing is damaged in the process of removing the me- chanical seal seat, install a new oil seal. 5. Remove the volute housing from the gearbox. 5.1 Secure the pump gearbox to prevent it from shifting position. 8. Install the volute housing. 8.1 Carefully slide the volute housing over the impeller shaft. 5.2 Remove the three 1/2–13 x 2 bolts that connect the volute housing to the pump gearbox. 8.2 Align the slinger with the impeller shaft. 8.3 Align the front impeller shaft bearing with the cavity in the rear of the volute hous- ing, then slide them together. 5.3 Separate the volute housing from the pump gearbox. 6.

Lay the volute housing front side down. With a 1/4-inch diameter roll pin punch, push the me- chanical seal seat out of the seal box. 8.4 Install the attaching bolts, with spacers, then tighten the bolts to 70 lbf·ft (95 N·m). CAUTION The use of any petroleum product to lubricate the mechanical seal will result in damage to the me- chanical seal. Business Class M2 Workshop Manual, Supplement 8, September 2005 110/1