PowerFlow Fire Pump 90.01 Troubleshooting Troubleshooting Simultaneous oil and water leaks are uncommon. Normally, a water leak indicates that a line has come loose or is broken. Gaskets are used between mat- ing surfaces without sealant. If a leak is present at a gasket-mating surface, whether oil or water, the com- ponents should be disassembled and repaired. Lack of use causes many problems for fire pumps and fire pump components. IMPORTANT: The entire pumping system should be exercised weekly. This routine procedure should include all discharge valves and suction valves.

Be certain when a device indicates it is not working that it is not a simple electrical problem, such as a burned-out indicator bulb. Abuse of the fire pump is rarely a problem. If the pump and pump components have been abused, indications of problems may be fairly obvious. For example, bent controls are a common indicator. Troubleshooting Tables Problem—Pump Will Not Engage Problem—Pump Will Not Engage Possible Cause Remedy Parking brake not set. Set the parking brake. Transmission not in neutral. Shift transmission to neutral. Insufficient air supply. Repeat the recommended shift procedure: Check the air pressure gauges. This procedure requires at least 100 psi (689 kPa).

Shut the engine down and check for air leaks. Pump shift or application of parking brake attempted before apparatus was stopped. Release the braking system momentarily and repeat the recommended shift procedure. * * This condition is known as "Butt Tooth," which occurs when the transmission shifts and the shift gear-teeth and the teeth on the drive gear do not line up and "butt" up against each other. The American LaFrance fire pump transmission is designed with a sliding shift collar. Therefore, the occurrence of "Butt Tooth" will be rare. Problem—Pump Will Not Shift Problem—Pump Will Not Shift Possible Cause Remedy Battery voltage low. Turn off accessories.

Check the charging system of the apparatus. Inspect the batteries. If okay, recharge and try shift again. Interface/Interlock module not receiving proper inputs. Check the Officers Information Center output. Transmission not receiving lock-up input. Check output to transmission with Prolink. Problem—Pump Will Not Prime Problem—Pump Will Not Prime Possible Cause Remedy Low battery voltage. Increase the engine speed 1000 to 1200 rpm for temporary support for electrical system requirements and primer operation. * Worn or damaged priming system. Perform the "Dry Vacuum Test," which follows the troubleshooting tables in this subject.

If pump is tight but primer develops less than 22 inches of vacuum, the primer pump, motor, or priming valve may be worn or damaged. Business Class M2 Workshop Manual, Supplement 8, September 2005 300/1