PowerFlow Fire Pump 90.01 Troubleshooting Problem—Pump Will Not Prime Possible Cause Remedy Primer not operated long enough. Operate for 30 seconds for pump up to 1250 gpm or for 45 seconds for 1500 and up gpm pump. Add 15 additional seconds if priming from front or rear suction. Do not run primer over 45 seconds. Stop and check for causes. Suction lifts too high. Do not attempt lifts exceeding 22 feet, except at low elevations. Suction strainer blocked. Check and clean. Air pocket in suction hose or pump. Place suction hose lower than suction intake. Slightly open a discharge valve momentarily to release trapped air. Air leaks.

Perform the "Dry Vacuum Test," which follows the troubleshooting tables in this subject. Then, shut engine off and listen for air leaks. Pressurize the discharge side of the pump with approximately 100 psi (689 kPa) from the hydrant, and check for water leaks. Check connections and gaskets. * Electric primer does not require engine speed to be increased for operation. A primer can and will draw in excess of 300 amps and primer operation can last 45 seconds. Problem—Pump Loses Prime Problem—Pump Loses Prime Suction lifts too high. Do not attempt lifts exceeding 22 feet except at low elevations. Possible Cause Remedy Suction strainer blocked. Check and clean. Air leaks.

Check all connections and gaskets. Perform the "Dry Vacuum Test," which follows the troubleshooting tables in this subject. Pump pressure is too low when discharge appliance is opened. Prime the pump again. Raise pump pressure higher and open the discharge appliance slowly. Problem—Pump Primer Does Not Operate Properly Problem—Pump Primer Does Not Operate Properly Does not operate electrically. Check the batteries, connections, primer, and primer control. Check the control switch and solenoid on the primer. If the primer has not been used recently, it could be frozen. It should, if contact is still being made internally, show heavy current draw.

Possible Cause Remedy Primer is slow or lower than normal. Check batteries, wiring, and connections. A large quantity of suction hoses or suction pipes can exceed primer capabilities. Too small diameter, or too long a length of piping between primer and pump can exceed primer capabilities. Lift not to exceed 20 feet (6 m), and 10 feet (3 m) for testing. The primer pump itself may be worn out. Pulls some prime. The primer pump could be in need of repairs or cleaning. Check for air leaks, and verify that the priming valve is not sticking. Pulls full prime. Check for air leaks. Check for clogged inlet strainer and screens. Check that the suction hose is submerged in adequate water supply.

Check for air pockets and air accumulation in piping. Check for turbulence in piping. The pump impeller may be damaged or severely worn. Business Class M2 Workshop Manual, Supplement 8, September 2005 300/2