SERDIA PARAMETERS TERMINOLOGY EXPLANATIONS: Acceler(SWG1): Accelerator pedal sensor (setpoint generator 1), Input 24 FS Hand throttle(SWG2): Hand throttle potentiometer (setpoint generator 2), Input 20 FS GENERAL PROCEDURE DURING CALIBRATION PROCESS: Select calibration size in upper window. Move accelerator pedal/hand throttle potentiometer to desired position. "Get value" switch activated: Actuate switch, the calibration value assigned to the position is shown in the editing field. "Get value" switch not activated: Enter calibration value in editing field. Upload calibration value with "PC->ECU" to ECU. Save calibration value with "Save in ECU" in ECU. Switch ignition on/off.
EXPLANATION OF FUNCTION SWITCH: Get value: If the "Get value" switch has been set to activated, you can fetch the calibration value belonging to a pedal po- sition using this switch. PC->ECU : The calibration value displayed is uploaded to the ECU. Save in ECU (only applies for EMR): The calibration data are permanently saved in the ECU. 20-33