SERDIA ERROR MEMORY 1 Switch to SWG 2 (if SWG 2 availabtel. Fixed speed with 2% speed droop is set. 2 Switch to SWG 1 (if SWG 1 available). Fixed speed vyilh 2% speed droop is set. 3 Electronics temperature is evaluated. 4 Continued running with reduced rated speed, if speed sensor 2 is available. 5 Injected fuel limitation (if activated). 6 The measured value exceeds maximum speed. 7 Speed sensor 2 not available or defective. 20-37 Error pilot lamp Error messages (only readable with SERDIA) Possible causes n. O.K Remedy Type of error Error location Flashing (Engine off) (5) Shutoff limit exceeded/ fallen below • 8305:Speed monitoring • 8345:Eng.OFF->CoolantTemp- Monit.
• 8365:Eng.OFF->OilPressMonit • 8405:Actuator (positioner, travel meter, fuel rack) Overspeed reached Temperature alarm limit exceeded for too long. Fallen below oil pressure alarm limit for too long. OK ↓ Faulty configuration (e.g. overrun cond. OFF) Actuator defective → → → Check coolant Check oil level Check data in SERDIA menu "Configuration" and change if necessary Replace actuator Engine start not ipossible a) Flashing (0) Broken cable or short-circuit • 8210:Data loss EEPROM • 8220:Data loss coil data • 8020:ECU (positioner actuation) Battery or cable harness defective, ECU failure → Check battery. Check cable harness. Replace ECU.
b) Flashing or Permanent light Error in central electronics, program in EMR was not executed → Replace ECU c) 0ff (0) Broken cable or short-circuit • 8170:(M13)Speed 1, camshaft7 Plug-in connection interrupted OK ↓ Plug-in contacts conta- minated or corroded OK ↓ Actuator defective OK ↓ Cable harness defective → → → → Restore plug-in connection Clean connector and replace if necessary Replace actuator Check cable harness and re- place if necessary (5) Shutoff limit exceeded/ fallen below • 8405: Actuator (positioner, travel meter, fuel rack) Actuator defective → Replace actuator