Deutz — OPERATION

AIR CONDITIONING SYSTEM OPERATION OF THE AIR CONDITIONING SYSTEM The compressor (1) is driven from the crankshaft via a drive- belt and pulley with an electromagnetic clutch (1a), which is operated from a switch on the control panel. The system is protected by a safety pressure switch, which performs the following functions: 1 - To inhibit engagement of the electromagnetic clutch (1a) when the system pressure falls below 2.4 bar (34.8 psi) as a result of incomplete charging or refrig- erant loss. 2 - To disengage the clutch (1a) and thereby stop the compressor when the pressure exceeds the permit- ted maximum of 28.5 bar (413.3 psi) (generally as a re- sult of over-heating).

The refrigerant (in vapour state) is drawn in by the com- pressor where it is compressed, causing the temperature of the vapour to rise; the refrigerant flows to the condenser (2), where its heat is radiated to the air flow and it is thus cooled to the point where it condenses to high-pressure liquid. On leaving the condenser, the liquefied refrigerant flows to the receiver-drier (3) which performs three main functions: to filter out any impurities, to absorb any water in the circuit, and finally, to act as a storage reservoir.

On leaving the receiver-drier, the clean, dry liquid passes to the evaporator (6) through an expansion valve (5), which meters the flow of refrigerant into the evaporator to ensure optimum evaporation. In the evaporator, the refrigerant is heated and expands to the point of evaporation with an ambient temperature of around -- 8°C (17.6°F). The temperature of the air flow over the evaporator (6) gen- erated by the centrifugal blowers (8) is significantly higher than -- 8°C (17.6°F), and therefore it gives up its heat to the refrigerant, causing it to boil and evaporate. On leaving the evaporator (6), the refrigerant returns to the compressor (1) to repeat the cycle.

The removal of heat from the ambient air flowing over the evaporator causes the moisture in the air to condense, and the air is thus dehumidified; the moisture condenses on the fins of the evaporator, where, if it is not maintained at tem- perature above 0°C (32°F), it will freeze and comprise the efficiency of the evaporator.

The task of maintaining the evaporator at a temperature above 0°C (32°F) (and within the optimum temperature for efficient heat exchange), is performed by an electronic tem- peratures sensor (7); this sensor disengages the compres- sor clutch (1a) when the temperature falls to the lower limit and engages the clutch (1a) when the evaporator temper- ature reaches an upper limit. The condensate that forms on the evaporator fins contains dust, pollen and other particles suspended in the air; con- tinuous condensation thus has the effect of purifying the air, and the drips of condensate are conveyed out of the vehicle via two ducts.

A fixed quantity of moisture-free oil is added to the circuit in order to lubricate all the mechanical components of the system; a certain percentage of this oil continuously circu- lates in the form of an oil mist, thereby lubricating the com- pressor (pistons and bearings) and the expansion valve. 30-35