RECHARGING THE AIR CONDITIONING SYSTEM After flushing, the moisture-free oil recovered during the discharging operation must be re-introduced into the sys- tem, followed by the refrigerant. Quantity of refrigerant (R134a): 1600 g (56.4 oz.) Quantity of oil: the quantity recovered. If the system has to be discharged and flushed in or- der to renew a system component, the quantity of oil in the replaced component must be measured and the same amount of new oil must added to that re- covered with the refrigerant. For details of the oil and refrigerant recharging pro- cedure, refer to the instructions supplied with the service machine. 30-38