Deutz — DISCHARGING, FLUSHING AND RECHARGING THE AIR CONDITIONING SYSTEM

RECHARGING THE AIR CONDITIONING SYSTEM DISCHARGING, FLUSHING AND RECHARGING THE AIR CONDITIONING SYSTEM 1 - Before discharging, flushing and recharging the air conditioning system, inspect the system for leaks using a suitable leak detector. d - Separation of the moisture-free oil from the liquid refrigerant and determination of its quantity by weight. e - Recharging the system with exactly the same amounts of refrigerant and oil as those recov- ered. f - Measuring the system delivery side pressure and return pressure (low pressure). 2 - In order to carry out the system servicing oper- ations you will require a dedicated servicing ma- chine capable of performing the following tasks:

a - Aspiration of the refrigerant fluid. b - Creation of a high vacuum to purge the sys- tem of contaminants. c - Filtration of the recovered refrigerant. 1. Discharging the system 1 - Connect the service machine to the high pressure service valve (1) and follow the specific instructions for the service machine to discharge the system. 2 - Disconnect the system component to be renewed or overhauled immediately after the service machine stops; plug the open ends of the system pipes as quickly as possible. 1 F0044080 2. Flushing and recharging the system Before each recharging, the system must be purged of all air, moisture and contaminants (oxides, deposits).

This entails creating a high vacuum within the system to evaporate any moisture present. The vapour, when extract- ed, draws with it any contaminants present in the system. For the flushing and recharging operations, the ser- vice machine must be connected to the high (1) and low (2) pressure service valves. 1 Maximum vacuum” must be maintained for at least 10 minutes. F0044090 2 F0044100 30-37