Deutz — REFITTING

ACCELERATOR POTENTIOMETER RENEWAL OF THE ACCELERATOR POTENTIOMETER Remove the battery cover and disconnect the nega- tive battery lead (–). 1 - Loosen the grub screw, remove the accelerator pedal (1) and remove the front floor mat (2). 1 2 F0030550 2 - Unplug the connector (3). 3 - Remove the screws (4) and remove the potentiometer (5). 4 5 3 F0030560 REFITTING THE ACCELERATOR POTENTIOMETER Refitting is the reverse of removal. 1 - When fitting a replacement potentiometer, check the engine speed settings with the programming/diag- nostics tester. 30-115