CONTROL PANELS AND LEVERS OF THE AUXILIARY SERVICE VALVES AND THE PTO. REMOVAL OF THE CONTROL PANELS AND LEVERS OF THE AUXILIARY SERVICE VALVES AND THE PTO The illustrations refer to a model equipped with a front PTO. Disconnect the negative lead (-) from the battery. 2 1. Remove the lift control panel 1 - Unscrew and remove fixing screws (1) of the lift control panel (2). 1 F0045480 2 - Unplug the connector (3) and remove the assembly (2). 2 3 F0045490 3 - Only in the case of testing or renewal of the po- tentiometers . Unscrew and remove the screws (4) and remove the lower cover (5). 5 4 F0045500 2.
Removal of the auxiliary service valve control levers 1 - Remove the lift control panel as described in the pre- vious paragraph. 7 2 - Unscrew and remove fixing screws (6) of the control levers assembly (7). 6 F0045510 30-163