Deutz — REFITTING

AIR CONDITIONING EVAPORATOR 6 - Remove the bolts and lift the seat support (6). 7 - Remove the screws and remove the cover (7) of the air conditioning assembly. 6 7 F0021590 8 - Disconnect the inlet (8) and outlet (9) pipes from the evaporator. Immediately seal the ends of the pipes (8) and (9) to prevent atmospheric moisture from getting into the air conditioning system. 2 8 9 9 - Release the rubber diaphragm (10). F0021650 10 - Lift up the evaporator (11); remove the temperature sensor (12) and place it on one side. 3 11 - Remove the evaporator (11). 10 REFITTING THE EVAPORATOR Refitting is the reverse of removal. 1 Quantity of R134a:

1600 g (56.4 oz.) After recharging the system, check the seals on the pipes (R and S) and throughout the system us- ing a leak detector. F000 1062 2 11 High pressure fitting (5/8’ - 18UNF): 13,6–20,3 Nm (10 – 15 lb.ft.) Low pressure fitting (7/8’ - 14UNF): 35,3–42 Nm (26 – 31 lb.ft.) 12 3 Check that the temperature sensor is securely fixed. 1 - Carefully check the seal around the upper cover (7). F000 0941 30-180