Deutz — 3.5 CAN-Status

SERDIA MEASURED VALUES Bus Off: Counter that indicates how often the EMR has separated from the CAN bus because of constant errors (Can- BusOffCounter 0 to 255, byte).toma Status: CanOnline indicates whether the EMR is active on the CAN bus. Via the ISO 9141 interface a value 1 is sent for on- line and a value 0 for offline. The program SERDIA displays the text "online" (for value 1) or "offline" (for value 0). Phase: The variable CanSetPointPhase (0 to 255, byte) is sent via the ISO 9141 interface. This variable displays the pro- cedure with regard to time of the setpoint assignments: Error information:

The EMR sends an error number CanErrorNumber (0 to 255, byte) specifically for CAN bus errors via the-ISO 9141 interface. A text is assigned in SERDIA to these numbers, which is displayed in the window of the CAN in- terface. Time-Out errors of receipt messages require special handling. All of these are reported with an error number To identify which message causes a Time-Out error, SERDIA proceeds as follows: CanRxObjActive indicates the active, i.e. actually received messages in bits. CanConf_bits contains the configured receipt messages in bits. 20-19 Phase Text 0 0: Engine standstill, Initialization 1 1: Engine standstill, phase! , no CAN error 2 2:

Engine standstill, phase2, CAN timeout error 3 3: Engine start, ... until idling speed is recognized 4 4: Engine runs, wait for CAN setpoint 5 5: Engine runs, setpoint preset via CAN is allright 6 6: Engine runs, emergency op., setpoint preset via CAN failed 7 7: This phase doesn't exist Code Text 0 0: No fault existing 1 1: Message request not received bei controller object 15 2 2: Invalid controller object 3 3: controller object multi assignment 4 4: CAN active, but no message activated 5 5: Diagnosis object not activated 6 6: Scan rate 0 in diagnosis message 7 7: Scan rate 0 in measure value telegram 8 8: preset engine speed config.6 does not match TSC2 activation 9 9:

TSC1 activated, but 'Setpoint eng. speed not set to 6’ 10 10: ”GovernConf=6,neither TSC1 nor function shift is activated 11 11: GovernConf=6 & Setp.eng.speed=6', but TSC1 is not activated 12 12: TSC1 activated, but Governor config!=6 13 13: TSC1NotAct&FunctShiftAct& GovernConf.!=6 => ShiftMGovernMode!=0 14 14:

TSC1Act&FunctShiftAct&GovernConf.=6'=--'ShiftMaskGovernMode!=0 100 100 Receipt message failed 101 101 Setpoint telegram failed w.eng.idle (repl, value) 102 102 Setpoint telegram missing w.eng.idle due to low battery voltage 103 103 Setpoint telegram missing after eng.start due to low battery 104 104 Setpoint telegram missing after eng,start, repl.value used 105 105 Setpoint telegram missing during eng.open, repl.value used