Komatsu — LOCATIONS

. ATTACHMENTS AND OPTIONS MACHINE READY FOR ATTACHMENT Cracking pressure of low-pressure safety valve Main valve 24.53 MPa (250 kg/cm 2 , 3550.0 PSI) Selector valve 17.17 MPa (175 kg/cm 2 , 2490.0 PSI) Breaker Circuit Additional Oil Filter This filter (6) is used to prevent deterioration of the hydraulic oil when using the breaker. The oil flows through this only when the selector valve is at the breaker position. NOTICE Always install an additional filter in the return circuit on machines equipped with a hydraulic breaker. Accumulator (for Low Pressure) (If equipped) This accumulator (7) is installed to protect an oil cooler, when a breaker is used.

Consult each manufacturer of breaker to decide if an accumulator may well be installed in your machine. 6 - 8 Accumulator (for High Pressure (If equipp When a b reaker is in use, this accumulator (5) serves to assure the number of breaker hammering by lowering pulsation in the hydraulic pump discharging unction is to protect th e pump.

Consult e ach manufacturer o f breaker to decide if an accumulator may well be installed on you r machine Table for Additional Circuit a nd Parts Required for Mounting Breaker ( { white circlet indicates an item necessary to i nstal l) Additional filter Accumulator Low-pressure safety valve Attachment circuit Control circuit Main valv e Selector valve Hydraulic breaker { { (go/return) { { {