Komatsu — TRAVEL MOTOR

TRAVEL MOTOR STRUCTURE, FUNCTION, & MAINTENANCE STANDARD Operation of brake when traveling downhill If the machine tries to run away when traveling downhill, the motor will turn under no load, so the pressure at the motor inlet port will drop, and the pressure in chamber S1 through orifices E1 and E2 will also drop. When the pressure in chamber S1 drops below the spool switching pressure, spool (19) is returned to the left, in the direction of the arrow by spring (20), and outlet port MB is throttled. As a result, the pressure at the outlet port side rises, resistance is generated to the rotation of the motor, and this prevents the machine from running away.

In other words, the spool moves to a position where the pressure at the outlet port MB balances the pres- sure at the inlet port and the force generated by the weight of the machine. It throttles the outlet port cir- cuit and controls the travel speed according to the amount of oil discharged from the pump. (Fig. 4) 2) Safety valve Function When travel is stopped (or when traveling downhill), the circuits at the inlet and outlet ports of the motor are closed by the counterbalance valve, but the motor is rotated by inertia, so the pressure at the outlet port of the motor will become abnormally high and dam- age the motor or piping.

The safety valve acts to release this abnormal pressure and send it to the inlet port side of the motor to prevent damage to the equipment. Operation 1. When travel is stopped (or when traveling down- hill, rotating to right) When the motor inlet port pressure (pressure PA ) goes down, the pressure in chamber S1 also goes down. When it goes below the switching pressure of the spool, spool is returned to the left by spring (20), and outlet port passage B1 is throttled. When this happens, the motor continues to rotate under inertia, so the outlet pressure (pressure MB ) rises. (Fig. 5) If the pressure goes above the set pressure of suction- safety valve (18A), the poppet opens.

The oil then passes through large notch A1 in counterbalance valve spool (19) and flows to chamber MA in the cir- cuit on the opposite side. (Fig. 6) 2. When rotating to left The operation is the reverse of when rotating to the right. 10-108 PC210/240-7K