Komatsu — TRAVEL PPC SHUTTLE VALVE

STRUCTURE, FUNCTION, & MAINTENANCE STANDARD TRAVEL PPC SHUTTLE VALVE TRAVEL PPC SHUTTLE VALVE Function If the boom lever is set to the "RAISE" position or the arm lever is set in the "IN" or "OUT" position or the bucket lever is set in the "CURL" or "DUMP" posi- tion while the machine is travelling up a sharp slope, the travel PPC shuttle valve regulates the spool strokes of the boom, arm, and bucket control valves with the travel PPC pressure to limit the flow of the oil into the boom, arm, and bucket cylinders. When the strokes of the boom, arm, and bucket are regulated, the travel PPC pressure is applied through the circuit in the control valve.

Operation 1 When travel lever is in neutral The oil in stroke regulation signal chamber "a" is drained through orifices (5) and (6) of pistons (3) and (4) in the travel spring case and the travel PPC valve.If the boom lever is set to the "RAISE" position (or the arm lever is set in the "IN" or "OUT" position or the bucket lever is set in the "CURL" or "DUMP" position), spool (1) moves to the left until it reaches the end of spring case (2) (st0) . 10-112 PC210/240-7K