Komatsu — TRAVEL PPC VALVE

STRUCTURE, FUNCTION, & MAINTENANCE STANDARD TRAVEL PPC VALVE 12 3) Fine control (control lever returned) When lever (5) starts to be returned, spool (1) is pushed up by the force of centering spring (3) and the pressure at port P1 . Because of this, fine control hole f is connected to drain chamber D , and the pressurized oil at port P1 is released. If the pressure at port P1 drops too much, spool (1) is pushed up by metering spring (2), so fine control hole f is shut off from drain chamber D .

At almost the same time, it is connected to pump pressure chamber PP , so the pressure at port P1 supplies the pump pressure until the pressure recovers to a pres- sure equivalent to the position of the lever. When the control valve returns, oil in drain chamber D flows in from fine control hole f of the valve on the side that is not moving. It passes through port P2 and goes to chamber B to charge the oil. (Fig. 3) 4) At full stroke Lever (5) pushes down piston (4), and retainer (9) pushes down on spool (1). Fine control hole f is shut off from drain chamber D , and is connected to pump pressure chamber PP .

Therefore, the pilot pressure oil from the main pump passes through fine control hole f and flows to chamber A from port P1 to push the control valve spool. The return oil from cham- ber B passes from port P2 through fine control hole f and flows to drain chamber D . (Fig. 4) 10-124 PC210/240-7K