Komatsu — SOLENOID VALVE

STRUCTURE, FUNCTION, & MAINTENANCE STANDARD SOLENOID VALVE 12 1.Connector 2.Moving core 3.Coil 4.Spool 5.Block 6.Spring OPERATION WHEN SOLENOID IS TURNED OFF Since the signal current does not flow from the controller, solenoid (3) is turned off. Accordingly, spool (4) is pressed by spring (6) against the left side. By this operation, the pass from P to A is closed and the hydraulic oil from the main pump does not flow into the actuator. At this time, the oil from the actuator is drained through ports A and T into the tank. WHEN SOLENOID IS TURNED ON The signal current flows from the controller to solenoid (3), and the latter is turned on.