Komatsu — PPC ACCUMULATOR

STRUCTURE, FUNCTION, & MAINTENANCE STANDARD PPC ACCUMULATOR PPC ACCUMULATOR 1 1. Gas plug 2. Shell 3. Poppet 4. Holder 5. Bladder 6. Oil port 2 SPECIFICATIONS Type of gas : Nitrogen gas Gas capacity : 300 cc (for PPC) Max. actuating pressure:3.1 MPa(32 kg/cmІ) Min. actuating pressure: 1.2 MPa(12 kg/cmІ) 3 4 5 6 SBP00290 FUNCTION The accumulator is installed between the PPC control pump and the PPC valve. Even if the engine is stopped with the work equipment raised, pilot oil pressure is sent to the main control valve by the pres- sure of the nitrogen gas compressed inside the accu- mulator, so it si possible to lower the work equipment under its own weight.

OPERATION After the engine stops, when the PPC valve is at neu- tral, chamber A inside the bladder is compressed by oil pressure in chamber B. If the PPC valve is operated, the oil pressure in cham- ber B becomes less than 2.9 MPa (30 kg/cmІ), so the bladder expands under the pressure of the nitrogen gas in chamber A . The oil entering chamber B is sent as the pilot pressure to actuate the main control valve. 10-134 PC210/240-7K