Komatsu — ENGINE CONTROL

STRUCTURE, FUNCTION, & MAINTENANCE STANDARD ENGINE CONTROL 12 1. OPERATION OF SYSTEM Starting engine When the starting switch is turned to the START position, the starting signal flows to the starting motor, and the starting motor turns to start the engine. When this happens, the engine throttle and pump controller checks the signal from the fuel control dial and sets the engine speed to the speed set by the fuel control dial. 08903 Engine speed control The fuel control dial sends a signal to the engine throttle and pump controller according to the posi- tion of the dial.

The engine throttle and pump con- troller calculates the angle of the governor motor according to this signal, and sends a signal to drive the governor motor so that it is at that angle. When this happens, the operating angle of the gov- ernor motor is detected by the potentiometer, and feedback is sent to the engine throttle and pump controller, so that it can observe the operation of the governor motor. 08904 Stopping engine When the starting switch is turned to the STOP position, the engine throttle and pump controller drives the governor motor so that the governor lever is set to the NO INJECTION position.

When this happens, to maintain the electric power in the system until the engine stops completely, the engine throttle and pump controller itself drives the battery relay. 08905 PC210/240-7K 10-161