TESTING AND ADJUSTING SPECIAL FUNCTION OF MULTI-MONITOR PANEL Select the most favorite display unit from among the prepared three kinds, i.e. ISO, meter and inch. When changing one display unit for another, refer to "Unit" in the initial value setting of Service Menu. Abbreviations, ABN and NOR, stand for the following conditions. ABN: Abnormal, NOR: Normal 20-160 PC210/240-7K Code No. Item to be monitored Unit (Default: ISO) Remark ISO Meter Inch 043 Battery Charge Vol. V V V 044 Hydr. Oil Temperature ºC ºC ºF 045 Monitor Input 1 Key Switch ON/OFF Start ON/OFF Preheat ON/OFF Light ON/OFF Rad. level ON/OFF 046 Monitor Input 2 Aircleaner ON/OFF Eng. Oil Press. ON/OFF Eng. Oil Level.
ON/OFF Spare ON/OFF Battery Charge ABN•NOR 049 Monitor Input 3 Swing Brake Sw. ON/OFF Buzzer cancel Sw. ON/OFF Window Limit Sw. ON/OFF W Limit Sw. ON/OFF P Limit Sw. ON/OFF 200 Monitor Prog. Version Figure 201 Controller Prog. Version Figure