TESTING AND ADJUSTING SPECIAL FUNCTION OF MULTI-MONITOR PANEL 17. Function for Abnormality Record [02] The monitor panel records failures that occurred on the machines in the past after classifying them into failures in the electric system and those in the mechanical system. Information on them can be displayed through the following operation. 1) Selection of menu Select 02 Abnormality Record in the initial display of Service Menu and depress [ ] switch. 2) Selection of Submenu Select an appropriate item from Submenu in the Abnormality Record display and depress [ ] switch. 3) Information shown in display of Abnormality Record in the electrical system :
The numerator expresses sequence of failure occurrence, counting from the latest one. The denominator expresses the total number of a specific failure recorded. : Service Code : Abnormality Code No. (system in 4 dig- its and phenomenon in 2 digits) : Time elapsed since the occurrence of the first failure : Contents of failure Refer to "Table for Service Code and Ab- normality Code" in Operator's Menu. 4) Information shown in display of Failure His- tory in the mechanical systems : Record No. : Contents of Abnormality : Abnormality Code No. (system in 4 dig- its and phenomenon in 2 digits) : Total number of occurrence :
Service meter reading at the initial occurrence Refer to "Table for Service Code and Ab- normality Code" in Operator's Menu. PC210/240-7K 20-161 No. Abnormality Record Submenu 00 Return (termination of Abnormality Record) 01 Electrical System 02 Mechanical Systems