Komatsu — Failure Code in Mechanical System (Engine cooling water overheating)

TESTING AND ADJUSTING B@BCNS Failure Code in Mechanical System (Engine cooling water overheating) B@BCNS Electrical Circuit Diagram for Engine Cooling Water Temperature Sensor in Monitor Panel 20-384 PC210/240-7K User Code S ervice Code Failure Code Failure phenomeno Engine cooling water overheated n (in mechanical system) — — B@BCNS Failure content • The engine cooling water sensor inputted a signal of 102°C, while the engine was running. Response from • controller Response from controller Phenomenon occurring on • machine There is a possibility that the engine seizes, if it is kept running without a corrective action.

• Relative information • This Failure Code is recorded, if the engine cooling water temperature gauge is displayed in the red range, when the engine is running. Input from the engine cooling water temperature sensor (temperature) can be confirmed in the monitor function. (Code No. 041: Engine cooling water temperature) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Engine Overheating (system in normal condi- tion) ★Check the engine for the cause and damage, and repair it.

2 Engine cooling water temperature sensor defective (Internal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. E05 (male) Engine cooling water tem- perature Resistance value Between and Between and grounding 10 – 100 °C 90 – 3.5kΩ Above 1 MΩ 3 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Between wiring harness between P02 (female) and E05 (female) and grounding Resistance value Above 1 MΩ 4 Monitor panel defective ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. P02 (female) Engine water temperature Resistance value Between and Between and grounding 10 – 100 °C 90 – 3.5kΩ Above 1 MΩ