Komatsu — Failure Code in Mechanical System (Abnormally lowered radiator water level)

TESTING AND ADJUSTING B@BCZK Failure Code in Mechanical System (Abnormally lowered radiator water level) (Multi-monitor only) B@BCZK Electrical Circuit Diagram for Radiator Water Level Switch in Monitor Panel PC210/240-7K 20-385 User Code S ervice Code Failure Code Failure phenomenon Radiator water level abnormally lowered (in mechanical system) — — B@BCZK Failure content • The signal circuit in the radiator water level switch was opened (i.e. disconnected from grounding). Response from • controller None in particular Phenomenon occurring on • machine There is a possibility that the engine seizes, if it is kept running without a corrective action.

• Relative information • This Failure Code is recorded, if the radiator water level caution symbol is displayed in the monitor panel, when the engine is running. Input from the radiator water level switch (ON or OFF) can be confirmed in the monitor function. (Code No. 045: Monitor input 1) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Radiator water level low- ered (system in normal condition) ★Check the water level and refill cooling water.

(If this phenomenon occurs frequently, check the cause) 2 Radiator water level switch defective (Internal disconnection) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. A33 (male) Engine cooling water level Resistance value Between and When in normal condition Below 1 Ω When lowered Above 1 MΩ 3 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Wiring harness between P02 (female) and A33 (female) Resistance value Below 1 Ω Wiring harness between A33 (female) and grounding Resistance value Below 1 Ω 4 Monitor panel defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. P02 Engine water temperature Resistance value Between and grounding When in normal condition Below 1 V When lowered 20 – 30 V