Komatsu — INFORMATION CONTAINED IN TROUBLESHOOTING TABLE

TESTING AND ADJUSTING B@HANS Failure Code in Mechanical System (Hydraulic oil overheating) (Multi-monitor only) B@HANS Electrical Circuit Diagram for Hydraulic Oil Temperature Sensor in Monitor Panel 20-386 PC210/240-7K User Code Service Code Failure Code Failure phenomeno Hydraulic oil overheated n (in mechanical system) — — B@HANS Failure content • The hydraulic oil temperature sensor inputted a signal of 102°C, while the engine was running. Response from • controller None in particular Phenomenon occurring on • machine There is a possibility that the engine seizes, if it is kept running without a corrective action.

• Relative information • This Failure Code is recorded, if the hydraulic oil temperature gauge is displayed in the red range, when the engine is running. Input from the hydraulic oil temperature sensor (temperature) can be confirmed in the monitor function. (Code No. 044: Engine cooling water temperature) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Hydraulic oil overheat- ing (system in normal condition) ★Check the cause and damage to the hydraulic equipment, and repair it.

2 Hydraulic oil temperature sensor defective (Internal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. A61 (male) Hydraulic oil tempera ture Resistance value Between and Between and grounding 10 – 100 °C 90 – 3.5kΩ Above 1 MΩ 3 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Between wiring harness between P02 (female) an A61 (female) and grounding d Resistance value Above 1 MΩ 4 Monitor panel defective ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. P02 (female) Engine water tempera ture Resistance value Between and Between and grounding 10 – 100 °C 90 – 3.5kΩ Above 1 MΩ