TESTING AND ADJUSTING H-26, H-27 H-26 There is big shock when stopping swing H-27 There is big abnormal noise caused when stopping swing PC210/240-7K 20-623 Failure information • There is a big shock caused when stopping a swing motion. Relative information • Set the working mode at A mode for the troubleshooting. Presumed cause and stan- dard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of swing PPC valve ★Stop engine for preparations. Start troubleshooting at engine high idling.
Swing control lever PPC valve output pressure NEUTRAL 0 {0} Left or right Above 2.7 MPa {Above 28 kg/cm2} 2 Malfunctioning of swing PPC slow return valve The swing PPC slow return valve is presumed to malfunction. Check the valve itself. ★Whether the valve malfunctions or not may well be determined by swap- ping the right and left valves and watching the result. Failure information • There is a big abnormal noise caused when stopping a swing motion. Relative information • Set the working mode at A mode for the troubleshooting.
Presumed cause and stan- dard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of backpres- sure valve The backpressure valve is presumed to malfunction. Check the valve itself. 2 Malfunction of swing motor (safety valve) The safety valve in the swing motor is presumed to malfunction. Check the valve itself. 3 Malfunction of swing motor (suction valve) The seal in suction valve of the swing motor is suspected of defect. Check the seal itself. ★Whether the seal is defective or not may well be determined by swapping the right and left valves and watching the result.
4 Swing machinery defective The swing machinery is suspected of an internal failure. Check the inside of the machinery itself. ★A failure inside the swing machinery may well be determined by monitoring abnormal noise, abnormal heat generated or metal dust or chips contained in the drained oil.