Komatsu — Sec 30.pdf

TESTING AND ADJUSTING H-28 H-28 Swing natural drift is too big 20-624 PC210/240-7K Failure information (1) • Natural drift of the swing is too big (when the parking brake is activated). Relative information • When the emergency swing release switch is in the OFF position (this is a normal condition), the swing and parking brake is activated and the swing is fixed with a disc brake. Presumed cause and stan- dard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Swing and parking brake sole- noid valve malfunctioned ★Stop engine for preparations. Start troubleshooting at engine high idling.

Swing control lever Solenoid valve output pressure NEUTRAL 0 {0} Left or right 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Swing motor (parking brake portion) malfunctioned The parking portion of the swing motor is suspected of malfunctioning and interior failure. Check that portion directly. Failure information (2) • Natural drift of the swing is too big (when the parking brake is released). Relative information • When the emergency swing release switch is in the ON condition (this is an emergent condition), the swing and parking brake is released and the swing is retained only hydraulically.

Presumed cause and stan- dard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Swing control valve (spool) malfunctioned The seal in the spool of the swing control valve is suspected of defect. Check the spool itself directly. 2 Swing control valve (pressure compensation valve) malfunc- tioned The pressure compensation valve seal in the swing control valve is sus- pected of defect. Check the valve itself directly. 3 Swing motor (safety valve) defective The safety valve seal in the swing motor is suspected of defect. Check the valve itself directly. 4 Swing motor (suction valve) defective The suction valve seal in the swing motor is suspected of defect.

Check the valve itself directly. 5 Swing motor (check valve) defective The check valve seal in the swing motor is suspected of defect. Check the valve itself directly.