DISASSEMBLY AND ASSEMBLY OIL SEAL IN HYDRAULIC PUMP INPUT SHAFT 12 REMOVAL AND INSTALLATION OF PUMP INPUT SHAFT OIL SEAL IN HYDRAULIC PUMP INPUT SHAFT SPECIAL TOOLS INSTALLATION Install in reverse order of removal. *Distinction between new and existing part. Oil seal lip portion: Grease (G2-LI) REMOVAL Oil seal outer circumference: Grease (G2-LI) 1. Remove the hydraulic pump assembly, referring to the section of Removing Hydraulic Pump Assembly. Coat the oil seal outer circumference thinly with grease. Press-fit oil seal (3), using tool N . 2. Remove snap ring (1) and then remove spacer (2). 3. Pry off oil seal (3) with a screwdriver.