Komatsu — 24.10 EVERY 2000 HOURS SERVICE

24. SERVICE PROCEDURE 24. SERVICE PROCEDURE 4. Bleeding air from swing motor (Carry out this operation only when the oil in the swing motor case has been drained.) 1. Run the engine at low idling, remove air hose 1 and check that oil oozes out from air hose 1 . NOTICE When doing this, do not operate the swing. 2. If no oil oozes out, stop the engine, remove air hose 1 , then fill the motor case with hydraulic oil. 3. After completing the air bleed operation, tighten air hose 1 . 4. Run the engine at low idling, and slowly swing the upper structure at least 2 times uniformly to the left and right. NOTICE If the air is not bled from the swing motor, the motor bearings may be damaged. 5.

Bleeding air from attachment (when installed) If an attachment has been installed, run the engine at low idling and operate the attachment pedal repeatedly (approx. 10 times) until the air has been bled from the attachment and circuit. NOTICE If the method of bleeding the air from the attachment itself is specified by the manufacturer, bleed the air according to those specifications. 6. Operation 1. After completing the air bleed operation, stop the engine and wait for at least 5 minutes before starting operations. This will allow the bubbles in the oil inside the tank to escape. 2. Check that there is no leakage of oil, and wipe up any oil that has been spilled. 3-81